Notes on the quality of the p24 CFC data. The saturations of f12 and f11 look low using measued values. mean satf11: 0.872107 mean satf12: 0.943309 mean of 4 pts of outside air: f11air: 287.3 +/-6.9/1.0251 (data on SIO86 Scale). f12air: 563.65 +/- 7.48/0.98742 f11air about 8% high and f12air about 6% high. Contributes to low saturation level. Sfc ratio 0.45-0.5, for 1995, should have been about 0.5. dpw 5Apr2000 Using $data/Atm*/walker.out, the saturation.levels are: Mean sfc satuation of f11: 0.937025 Mean sfc satuation of f12: 0.998136 Based on: f11air = 265.8 f12air = 533.2 Not enough samples below 2000 m run. From report: Bottle blanks (from report) determined from test cast before and after station samples collected. f11 0.017-0.026 f12 0.015-0.022 Precision (mean of the percent deviation of 15 pairs): f12: 1.4% f11: 1.68% (13 pairs) sta 10 samp 203 (500m), conc and ratio looks high. There is no apparent O2 max. Flag ff11 = 3, ff12 = 3 sta 17 samp 209 (100m), conc f11 a little high, so ratio a little high relative to surrounding points. ff11 = 3? sta 20, samp 113 and 202 have high ratios relative to surrounding points. sta samp ff11 ff12 10 203 3 3 17 209 3 2